Three-phase electric motor 0,37 kW OMEC MOTORS

zł380.00 Grosszł308.94 Net

Three-phase electric motor 0,37 kW OMEC MOTORS.

Dispatch within:
5 days
Shipping cost incl. VAT:
from zł0.00
Availability:
Available
Weight:
0,15 kg
Secure payments
BLIK Przelewy24

Delivery with our partners

InPost Paczkomaty GLS DHL Pocztex

Available options depend on the products and delivery address.

Share

Three-phase electric motor 0,37 kW OMEC MOTORS

Item description:

  • Name: Three-phase electric motor
  • Quantity sold: 1 pcs.
  • Manufacturer: OMEC MOTORS
  • Power: 0,18 kW 2755 rev/min
  • Type: OMT4-63L
  • Voltage: 230/400 V 2-pole
  • Foot mounting: B3
  • Warranty 24 months
Three-phase electric motor 0,37 kW OMEC MOTORS
Three-phase electric motor 0,37 kW OMEC MOTORS

General information

Three-phase low-voltage squirrel-cage induction motors of the OMT4 series are manufactured in frame sizes 56÷160.

They have a monoblock housing cast from aluminium,

with feet that can be unscrewed and repositioned.

They are surface-cooled by air (TEFC).

The terminal box is normally located on top of the housing,

with cable outlets that can be rotated 4×90°.

OMT4 motors are intended for general industrial use. They can be

used to drive machinery and equipment operating

continuously without frequent starts and reversals.

Due to their internal protection rating (IP55), they can operate in

conditions where the surrounding air contains contaminants.

However, airborne dust concentration should not exceed 10 mg/m3.

These must not be chemically aggressive contaminants such as

acid and alkali vapours, or explosive mixtures.

The motors are suitable for operation in both directions.

Bearings

Standard motors are equipped with high-quality ball bearings

from SKF, FAG or NSK.

Double-sided enclosed bearings are used, filled with grease and

requiring no relubrication.

Standards

The motors are made in accordance with PN-EN 60034-1, IEC34-1/9,

PN-IEC72-1, IEC85, DIN 57530/VDE 0530 and their

related and equivalent standards.

Degree of protection: IP55, to PN-IEC 34-5

Cooling system: IC411, to PN-IEC 34-6

Mechanical design: B3; B35; B5; B14, V1, to PN-IEC 34-7

Insulation class: F

Temperature rise: as for class B (≤80°C)

Ambient temperature: -20…+40°C

Installation altitude: ≤1000 m above sea level

Declaration of conformity, CE marking

OMT4 series motors meet the requirements for safe

use and are supplied with a copy of the declaration of conformity

from the manufacturer. The CE marking is placed on the rating plate

of each motor.

The motors are designed, manufactured and tested under an

ISO 9001 quality assurance system.

WindingsWindings of the stator are made from high-quality

winding wires and class F (155ºC) insulating materials, while

maintaining temperature rises corresponding to class B (80ºC). This allows use with frequency converters (inverters) and in all climatic zones.

The rotor winding is a die-cast aluminium cage.

  • Brand
  • Reference
    6896837809
  • Waga
    0,15 kg
  • In stock
    1000 Items

  • Condition
    New
  • Sales unit
    pcs

Workplace safety warnings — in accordance with Regulation (EU) 2023/988 on general product safety:
1. Eye protection:
– Always wear safety goggles or a face shield to protect your eyes from sparks, particles and metal fragments.
2. Hearing protection:
– When working in a noisy environment, use ear defenders or earplugs to prevent hearing damage.
3. Respiratory protection:
– When working in dusty surroundings or in the presence of fumes, wear a filtering mask or an appropriate respirator.
– Ensure proper ventilation of the workstation.
4. Hand and skin safety:
– Use protective gloves that protect against mechanical injuries and chemicals.
– Where necessary, use protective creams to prevent irritation and dry skin.
5. Work clothing:
– Work in protective clothing resistant to sparks and splashes.
– Avoid loose clothing, jewellery and loose hair near machinery.
6. Fire risk:
– Keep the workstation free of flammable materials (e.g. paper, fabrics and chemicals).
– Keep a serviceable fire extinguisher close at hand and know how to use it.
7. Electrical hazards:
– Check the condition of cables and electrical equipment before use.
– Do not use electrical devices in damp conditions.
– Disconnect equipment from the power supply during maintenance or repairs.
8. Use of machinery and tools:
– Regularly inspect the technical condition of machines and tools.
– Use equipment in accordance with the manufacturer's instructions.
– Blades and tools should be maintained regularly and kept in good condition.
– Machines should be fitted with appropriate guards and protective devices.
9. Handling materials:
– Use handling equipment to move heavy components.
– Lift and carry using ergonomic practices to avoid injury.
10. Working with chemicals:
– Store chemicals in labelled, safe containers.
– Use substances in accordance with the manufacturer's instructions and occupational health and safety rules.
– Ensure air circulation when using chemicals.
Other important rules:
– Keep the workstation clean and tidy.
– Ensure adequate lighting in the working area.
– Provide occupational health and safety training.
– Carry out regular safety audits and comply with current regulations.

Comments (0)

No customer reviews for the moment.

4 other products in the same category

Viewed products

Loading...
Back to top