Pressure sensor SPAE-V1R-S4-PNLK-2.5K FESTO

zł685.90 Grosszł557.64 Net

Pressure sensor SPAE-V1R-S4-PNLK-2.5K FESTO.

Dispatch within:
3 days
Shipping cost incl. VAT:
from zł0.00
Availability:
Last items in stock
Weight:
4,233 kg
Secure payments
BLIK Przelewy24

Delivery with our partners

InPost Paczkomaty GLS DHL Pocztex

Available options depend on the products and delivery address.

Share

Approval RCM Mark
c UL us - Recognized (OL)
CE marking (see declaration of conformity) To EU EMC directive
In accordance with EU RoHS directive
KC marking KC-EMV
Certificate UL E322346
Material note RoHS-compliant
Measured variable Relative pressure
Measuring method Piezoresistive pressure sensor with display
Start value of pressure measuring range 0 bar
End value of pressure measuring range -1 bar
Overload range 5 bar
Operating medium Compressed air to ISO8573-1:2010 [7:4:4]
Notes on the operating medium Operation with lubricated air possible
Medium temperature 0 ... 50 °C
Ambient temperature 0 ... 50 °C
Analogue-to-digital converter resolution 10 Bit
Accuracy FS 1.5 %FS
Repeatability in ± %FS 0.3 %FS
Temperature coefficient in ± %FS/K 0.05 %FS/K
Switching output PNP/NPN, switchable
Switching function Freely programmable
Switching element function Normally closed contact
Normally open contact
Can be switched to
Max. output current 100 mA
Lower display limit range 0 %FS
Upper display limit range 99 %FS
Short-circuit protection Yes
Protocol IO-Link
IO-Link, protocol Device V 1.1
IO-Link, profile Smart sensor profile
IO-Link, function classes Binary data channel (BDC)
Process Data Variable (PDV)
Identification
Diagnostics
Teach channel
IO-Link, communication mode COM2 (38,4 kBaud)
IO-Link, support for SIO mode Yes
IO-Link, port type A
IO-Link, process data width OUT 0 Byte
IO-Link, process data width IN 2 Byte
IO-Link, process data content IN 14 bit PDV (pressure measurement)
2 bit BDC (pressure monitoring)
IO-Link, minimum cycle time 3 ms
IO-Link, required data storage 0.5 Kilobyte
Operating voltage range DC 18 ... 30 V
Reverse polarity protection For all electrical connections
Electrical connection 3-wire
Cable
Open end
Cable length 2.5 m
Mounting method plug-in
Mounting position Any
Pneumatic connections Plug-in sleeve QS-4
Product weight 40 g
Housing material Reinforced PA
Sealing ring material NBR
Display type LED indicators
2-digit
Displayable unit(s) %FS
Switching status indicator Yellow LED
Setting options IO-Link
Teach-In
Using display and buttons
Protection PIN-Code
Threshold setting range 1 ... 98 %
Degree of protection IP40
Corrosion resistance class CRC 2 – Moderate corrosion resistance

  • Brand
  • Reference
    SKY200474
  • Waga
    4,233 kg
  • In stock
    1 Item

  • Condition
    New
  • Sales unit
    pcs

Workplace safety warnings — in accordance with Regulation (EU) 2023/988 on general product safety:
1. Eye protection:
– Always wear safety goggles or a face shield to protect your eyes from sparks, particles and metal fragments.
2. Hearing protection:
– When working in a noisy environment, use ear defenders or earplugs to prevent hearing damage.
3. Respiratory protection:
– When working in dusty surroundings or in the presence of fumes, wear a filtering mask or an appropriate respirator.
– Ensure proper ventilation of the workstation.
4. Hand and skin safety:
– Use protective gloves that protect against mechanical injuries and chemicals.
– Where necessary, use protective creams to prevent irritation and dry skin.
5. Work clothing:
– Work in protective clothing resistant to sparks and splashes.
– Avoid loose clothing, jewellery and loose hair near machinery.
6. Fire risk:
– Keep the workstation free of flammable materials (e.g. paper, fabrics and chemicals).
– Keep a serviceable fire extinguisher close at hand and know how to use it.
7. Electrical hazards:
– Check the condition of cables and electrical equipment before use.
– Do not use electrical devices in damp conditions.
– Disconnect equipment from the power supply during maintenance or repairs.
8. Use of machinery and tools:
– Regularly inspect the technical condition of machines and tools.
– Use equipment in accordance with the manufacturer's instructions.
– Blades and tools should be maintained regularly and kept in good condition.
– Machines should be fitted with appropriate guards and protective devices.
9. Handling materials:
– Use handling equipment to move heavy components.
– Lift and carry using ergonomic practices to avoid injury.
10. Working with chemicals:
– Store chemicals in labelled, safe containers.
– Use substances in accordance with the manufacturer's instructions and occupational health and safety rules.
– Ensure air circulation when using chemicals.
Other important rules:
– Keep the workstation clean and tidy.
– Ensure adequate lighting in the working area.
– Provide occupational health and safety training.
– Carry out regular safety audits and comply with current regulations.

Comments (0)

No customer reviews for the moment.

4 other products in the same category

Viewed products

Loading...
Back to top