BCG 30E liquid for sealing central-heating systems with a leak of 30 litres FLEXIBLE 2,5 l

zł1,108.81 Grosszł901.47 Net

Liquid BCG 30E for sealing central-heating systems with a leak of 30 litres FLEXIBLE 2,5 l.

Dispatch within:
1 day
Shipping cost incl. VAT:
from zł0.00
Availability:
Available
Weight:
0,3 kg
Secure payments
BLIK Przelewy24

Delivery with our partners

InPost Paczkomaty GLS DHL Pocztex

Available options depend on the products and delivery address.

Share

BCG 30E liquid for sealing central-heating systems losing up to 30 litres of water per day.

The liquid is a self-sealing agent eliminating water losses up to 30 litres per day in heating systems supplied by oil boilers, gas boilers, gas water heaters or oil/gas condensing boilers. BCG 30E seals all materials (plastics, metals, press-fit systems, underfloor heating). 

BCG 30E forms a flexible seal at the leak. While in the system being sealed, the agent crystallises on contact with atmospheric air at the leak. The leak closes mechanically on its own.

Sealing individual pipe circuits in the heating system: Underfloor-heating pipes or risers can be sealed separately. Connect the isolated loop or riser to a device (pump) ensuring continuous water circulation in the heated closed circuit. Leave the circuit running for at least 2 days. During this time, raise the circuit pressure to operating pressure. Then drain and flush the riser or loop, reconnect it to the heating system, fill and start it. Mixing ratio: 1,0 l BCG agent to 100 l heating water.

Sealing pipe circuits in a heating system made with press fittings: For press-fit systems, the damaged riser or part of the heating system being sealed can be shut off and permanently separated using a heat exchanger. Introduce the sealing liquid into the heating circuit using a filling pump. BCG 30E must remain in the system (long-term action)! Mixing ratio: 1,0 l BCG agent to 100 l heating water.

THE SEAL IS:

  • durable and resistant to ageing,
  • resistant to high temperatures and pressure.

TIPS!

  • Equipment safety: Correct use does not damage pumps or control valves.
  • Other applications: For leaks in combustion chambers or boilers, use BCG 24, BCG Spezial or BCG TD.
  • System preparation: Before using the product, we recommend thoroughly flushing the system to remove deposits and contaminants. Check whether the heating system contains corrosion inhibitors, antifreeze agents or salts. If so, drain the system and flush it with water, then refill it and seal according to the instructions. 

INSTRUCTIONS FOR USE:

  • Preparation: Fully open all mixing valves and radiator thermostatic valves. Vent the circulation pumps and leave them running. Remove filters.
  • Draining water: Drain an amount of water from the system corresponding to the required dose of BCG 30 E.

APPLICATION:

  • Shake the BCG 30 E canister thoroughly.
  • Introduce the required amount of BCG 30 E (see table) in diluted form through the filling/drain valve (KFE).
  • Empty and rinse the canister with water to introduce residual product into the circuit.

SEALING PROCEDURE:

  • The heating system must run continuously for the first 7 hours without reducing temperature (e.g. without night mode).
  • Depending on conditions, sealing takes place within 1 or several days.
  • The agent must remain in the system and minimum water circulation must be maintained.

IMPORTANT: If the boiler is covered by the manufacturer’s warranty, we recommend system separation (heat exchanger) to isolate the boiler from the part of the system being sealed.

SAFETY AND STORAGE:

  • Precautions: Observe the general safety rules for working with chemicals.
  • Warning: Keep away from children!
  • In the event of a spill or leak: wash floors thoroughly and immediately with plenty of water.
  • Disposal: See safety data sheet.
  • Shelf life: 5 years from the date of manufacture.
  • Storage conditions: Protect from frost.
Technical data
Capacity
2500 ml
Form
Canister

  • Brand
  • Reference
    4002530
  • Waga
    0,3 kg
  • In stock
    10 Items
  • EAN13
    4010006025019

  • Condition
    New
  • Sales unit
    pcs
  • Brand
    Other
  • Pack volume [ml]
    2500

Workplace safety warnings — in accordance with Regulation (EU) 2023/988 on general product safety:
1. Eye protection:
– Always wear safety goggles or a face shield to protect your eyes from sparks, particles and metal fragments.
2. Hearing protection:
– When working in a noisy environment, use ear defenders or earplugs to prevent hearing damage.
3. Respiratory protection:
– When working in dusty surroundings or in the presence of fumes, wear a filtering mask or an appropriate respirator.
– Ensure proper ventilation of the workstation.
4. Hand and skin safety:
– Use protective gloves that protect against mechanical injuries and chemicals.
– Where necessary, use protective creams to prevent irritation and dry skin.
5. Work clothing:
– Work in protective clothing resistant to sparks and splashes.
– Avoid loose clothing, jewellery and loose hair near machinery.
6. Fire risk:
– Keep the workstation free of flammable materials (e.g. paper, fabrics and chemicals).
– Keep a serviceable fire extinguisher close at hand and know how to use it.
7. Electrical hazards:
– Check the condition of cables and electrical equipment before use.
– Do not use electrical devices in damp conditions.
– Disconnect equipment from the power supply during maintenance or repairs.
8. Use of machinery and tools:
– Regularly inspect the technical condition of machines and tools.
– Use equipment in accordance with the manufacturer's instructions.
– Blades and tools should be maintained regularly and kept in good condition.
– Machines should be fitted with appropriate guards and protective devices.
9. Handling materials:
– Use handling equipment to move heavy components.
– Lift and carry using ergonomic practices to avoid injury.
10. Working with chemicals:
– Store chemicals in labelled, safe containers.
– Use substances in accordance with the manufacturer's instructions and occupational health and safety rules.
– Ensure air circulation when using chemicals.
Other important rules:
– Keep the workstation clean and tidy.
– Ensure adequate lighting in the working area.
– Provide occupational health and safety training.
– Carry out regular safety audits and comply with current regulations.

Comments (0)

No customer reviews for the moment.

4 other products in the same category

Thin grease Wiko 400 ml spray
zł48.31 Grosszł39.28 Net
Rated out of 5 stars based on review(s)

Viewed products

Loading...
Back to top